pH and Temperature Meter (115 V, 50/60 Hz)
pH and Temperature Meter (115 V, 50/60 Hz)
For measuring ph values and temperature. Temperature compensation of the measured pH value is performed automatically with the connected temperature sensor. If no temperature sensor is connected, the ambient temperature of the device is used as the reference temperature. Includes a digital display for the pH value and temperature. The temperature can be displayed in °C or °K.
Allows a connection of all standard commercial pH sensors with a BNC plug and all NiCr-Ni thermocouples of type K.
Equipped with an integrated serial RS232 PC interface, as well as an analog output for connecting a recorder. Includes a Windows program and interface cable. The software allows a graphic representation of measured data as well as export of the data to a spreadsheet program.
pH measurement range: 0.10 pH to 14.00 pH
Accuracy: ±0.01 pH ± 1 digit
Input: BNC jack
Temperature measurement range: -20 to +1200°C
Accuracy: 0.5% of the display or ±0.1°C
Input: Thermocouple jack type K (NiCr-Ni)
Digital display: 4-digit LED, (7-segment)
Digit height:19 mm
Analog output: 100 mV/pH
Computer connection: RS232 serial interface for PC (DB9 plug)
Power consumption: 10 VA
Dimensions: 95 mm x 225 mm x 160 mm
Weight: 2.2 kg
Mains connection: 115 V, 50/60 Hz
For measuring ph values and temperature. Temperature compensation of the measured pH value is performed automatically with the connected temperature sensor. If no temperature sensor is connected, the ambient temperature of the device is used as the reference temperature. Includes a digital display for the pH value and temperature. The temperature can be displayed in °C or °K.
Allows a connection of all standard commercial pH sensors with a BNC plug and all NiCr-Ni thermocouples of type K.
Equipped with an integrated serial RS232 PC interface, as well as an analog output for connecting a recorder. Includes a Windows program and interface cable. The software allows a graphic representation of measured data as well as export of the data to a spreadsheet program.
pH measurement range: 0.10 pH to 14.00 pH
Accuracy: ±0.01 pH ± 1 digit
Input: BNC jack
Temperature measurement range: -20 to +1200°C
Accuracy: 0.5% of the display or ±0.1°C
Input: Thermocouple jack type K (NiCr-Ni)
Digital display: 4-digit LED, (7-segment)
Digit height:19 mm
Analog output: 100 mV/pH
Computer connection: RS232 serial interface for PC (DB9 plug)
Power consumption: 10 VA
Dimensions: 95 mm x 225 mm x 160 mm
Weight: 2.2 kg
Mains connection: 115 V, 50/60 Hz